Dyndrite opens complete LPBF scan-card control on Xact Metal systems
Native arcs, Bézier curves, wobble, pulsing and power ramps can be programmed directly on the XM200G platforms.

Dyndrite and Xact Metal have commercialised direct access to LPBF scan commands on XM200G and XM200G µHD systems. Dyndrite LPBF Pro sends native arcs, Bézier curves, wobble patterns, skywriting and delay parameters, pulsing and power ramps to the scan card rather than merely exporting sliced geometry. XM300G support is planned later.
What changes compared with conventional vectors
Many build-preparation chains approximate a curve with short straight segments. Dyndrite says a 10 mm-radius circle at 1 µm chord error needs about 222 vectors but can be one native arc. Fewer commands can reduce file size and describe motion continuously, although part quality still depends on optics, delays and the material process.
Direct access lets engineers assign different paths and laser dynamics to contours, infill, thin walls or local thermal loads. That is valuable in research and difficult alloys because strategy is not confined to a supplier's fixed recipes.
What the companies claim
The partners claim smaller files, fewer velocity and heat spikes, better surface and porosity, and improved handling of difficult angles. These are vendor claims: the release provides no blinded multi-material benchmark, CT dataset, fatigue result or statistical capability study.
A native arc is not automatically more accurate. Galvo calibration, controller interpolation, timing, spot size and the melt pool can alter the outcome. More degrees of freedom also enlarge the experimental space and create more failure opportunities without disciplined identification and version control.
Validation consequence
Users need separate checks of the CAD, geometry, toolpath and scan-card chain. Command count, path fidelity and timing require digital inspection, followed by witness builds measuring dimension, surface, density, microstructure and mechanics. Each software, firmware or calibration change needs a defined requalification scope.
The integration is available for XM200G and XM200G µHD and will be demonstrated at Formnext. Commercial availability is not automatic qualification for any material or regulated part.
Verified fact, vendor claim and conclusion
Supported machines and command types are verified in the partners' primary release. Quality and optical-wear benefits remain supplier claims. Our conclusion is that the real change is the boundary moving from a closed build processor toward open parametric path design. Reproducible benchmarks, auditable machine files and property data must prove industrial value.
Sources
The lead primary source is the joint Dyndrite–Xact Metal release dated 11 November 2026, supplemented by the LPBF Pro product page and TCT's 12 November trade report.